Configuration
The total area of the pavement section being inspected.
Simulations
Set to 1 for a single deterministic calculation. Increase for Monte Carlo analysis.
Distress Data
Instructions:
  • Enter Quantity and select Unit for each distress found.
  • Std Dev models measurement uncertainty. You can enter a fixed value OR use the "Model" button to set parameters A and B for the formula: StdDev = A * (Quantity ^ B). Note: A & B are assumed to be Imperial (SqFt) based. If metric is selected, conversion is applied automatically.
  • Apply ASTM Accuracy (10%/20%) - Sets Std Dev based on measurement type (Linear: 10%, Area: 20%) per ASTM D6433 Section 8.1.
Distress Type
Severity
Quantity & Unit
Uncertainty
Action

No distresses added yet. Click "Add Distress" or "Import CSV" to begin.

Analysis Results

-
Mean PCI
N/A
-
Median PCI
-
Standard Deviation
-
90% Confidence
Distribution Histogram
Condition Rating Probability
Calculation Details
Distress Type Severity Mean Quantity Density % Deduct Value (DV)
Calculation Trace (Max CDV Iteration): Shows step-by-step logic for determining Max CDV per ASTM D6433. The algorithm iteratively reduces the smallest deduct value to 2.0 until q=1.

-